Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e123181, dez 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1526439

ABSTRACT

Aim: To evaluate the effect of the exposure time and the type of composite in the production of radiographic artifact at the tooth / restorative interface. Materials and Methods: In 20 healthy bovine incisors, cavity preparations and class II restorations were made using composite resins Filtek Bulk Fill One (group 1) and Filtek Z350 (group 2). Then, the teeth were exposed to obtain digital radiographs, varying the exposure time by 0.07, 0.10, 0.14, 0.20 and 0.25s. The images were evaluated for investigation of the presence of artifact through the analysis of the modified number of pixels (QPXD) and the average gray value in class II (MGVR) restorations, using the Image J software (National Health Institute). Results: The presence of artifact was observed in all evaluated samples, regardless of the type of restorative material and the exposure time employed. There was no statistically significant difference in QPXD and MGVR between the resins used (ANOVA 2 factors, p p> 0.05). The MGVR analysis indicated that there were no statistically significant differences between resins or between exposure times (p> 0.05). There was a correlation between QPXD and MGVR (r = 0.29) for Filtek Bulk Fill One resin. Discussion: This study reveals the importance of attention to the region of the tooth-restoration interface by the Surgeon-Dentist, who must combine the radiographic findings diagnosed using digital tools to clinical signs in order to compose a unique therapeutic project with a real need for intervention, if there is such need. Conclusion: The presence of altered pixels on dentin in the region of the tooth-restoration interface was identified in all specimens. The variation in the exposure time as well as the type of the restorative composite did not influence the increase or decrease of QPXD and neither in MGVR. However, there was a correlation between QPXD and MGVR for Filtek Bulk Fill One resin.


Objetivo: Avaliar o efeito do tempo de exposição e do tipo de compósito na produção de artefato radiográfico na interface dente/material restaurador. Materiais e Métodos: Em 20 incisivos bovinos hígidos foram feitos preparos cavitários e restaurações classe II utilizando resinas compostas Filtek Bulk Fill One (grupo 1) e a Filtek Z350 (grupo 2). Em seguida, os dentes foram expostos para obtenção das radiografias digitais, variando o tempo de exposição em 0,07, 0,10, 0,14, 0,20 e 0,25s. As imagens foram avaliadas para investigação da presença de artefato através da análise do número de pixels modificado (QPXD) e do valor médio de cinza nas restaurações de classe II (MGVR), utilizando o software Image J (Instituto Nacional de Saúde, Bethesda, MD, EUA). Resultados: Observou-se a presença de artefato em toda amostra avaliada, independente de tipo de material restaurador e tempo de exposição empregado. Não se observou diferença estatisticamente significativa na QPXD e nos MGVR entre as resinas utilizadas (ANOVA 2 fatores, p p>0,05). A análise do MGVR indicou que não houve diferenças estatisticamente significativas entre as resinas nem entre os tempos de exposição (p>0,05). Observou-se uma correlação entre a QPXD e o MGVR (r=0,29) para a resina Filtek Bulk Fill One. Discussão: Como significado clínico, o presente estudo revela a importância da atenção à região da interface dente-restauração por parte do Cirurgião-Dentista, o qual deve aliar os achados radiográficos diagnosticados com o auxílio de ferramentas digitais aos sinais clínicos, para compor um projeto terapêutico singular com uma real necessidade de intervenção, caso haja. Conclusão: Foi identificado a presença de pixels alterados sobre a dentina na região da interface dente-restauração em todos os corpos de prova. A variação do tempo de exposição como também o tipo do compósito restaurador não influenciou no aumento ou diminuição do QPXD e nem tão pouco no MGVR. Contudo houve correlação entre o QPXD e o MGVR para a resina Filtek Bulk Fill One.

2.
Hist. ciênc. saúde-Manguinhos ; 29(3): 833-851, jul.-set. 2022. graf
Article in Portuguese | LILACS | ID: biblio-1405029

ABSTRACT

Resumo O artigo apresenta o modo como as imagens relativas aos conjuntos de química expressam as representações sobre a predominância do gênero masculino nas brincadeiras que simulam aspectos técnicos, gestuais, de laboratório, criando padrões de conduta que direcionam para a vocação profissional: o ser cientista. Foram privilegiadas as documentações produzidas pelas empresas Gilbert (1920) e Chemcraft (1922), presentes no acervo da Chemical Heritage Foundation (EUA). Discute-se o que Joan Scott chama de organização social da diferença sexual, enquanto são analisadas as ilustrações que privilegiam a dominância do gênero masculino, nas formas de "ser criança", brincando de cientista.


Abstract This article shows how images relating to chemistry sets express the predominance of the male gender in toys that simulate technical, gestural, and laboratory-related aspects of science, creating patterns of conduct towards the professional vocation of being a scientist. Priority is given to documents produced by the companies Gilbert (1920) and Chemcraft (1922) that are kept in the archives of the Chemical Heritage Foundation in the USA. What Joan Scott calls the social organization of sexual difference is discussed and the illustrations are analyzed, demonstrating a predominance of male figures showing how to "be a child," playing at being a scientist.


Subject(s)
Play and Playthings , Science/history , Social Dominance , Sex Characteristics , Sexism , Men
3.
Rev. bras. oftalmol ; 81: e0103, 2022. graf
Article in English | LILACS | ID: biblio-1407672

ABSTRACT

ABSTRACT Optical coherence tomography is often used for detection of glaucoma as well as to monitor progression. This paper reviews the most common types of artifacts on the optical coherence tomography report that may be confused with glaucomatous damage. We mainly focus on anatomy-related artifacts in which the retinal layer segmentation and thickness measurements are correct. In such cases, the probability maps (also known as deviation maps) show abnormal (red and yellow) regions, which may mislead the clinician to assume disease is present. This is due to the anatomic variability of the individual, and the normative database must be taken into account.


RESUMO A tomografia de coerência óptica é frequentemente usada para detectar glaucoma, bem como para monitorar a progressão. Este artigo analisa os tipos mais comuns de artefatos no relatório de tomografia de coerência óptica que podem ser confundidos com danos glaucomatosos. Nós nos concentramos principalmente nos artefatos relacionados à anatomia em que a segmentação da camada da retina e as medidas de espessura estão corretas. Nesses casos, os mapas de probabilidade (também conhecidos como mapas de desvio) mostram regiões anormais (vermelho e amarelo), o que pode induzir o clínico em erro ao supor que a doença está presente. Isto se deve à variabilidade anatômica do indivíduo, e o banco de dados normativo deve ser levado em conta.


Subject(s)
Humans , Glaucoma/diagnostic imaging , Artifacts , Tomography, Optical Coherence/methods , Posture , Retina/diagnostic imaging , Torsion Abnormality , Head Movements , Diagnostic Errors , Eye Movements , Fovea Centralis , Nerve Fibers/pathology
4.
Natal; s.n; 2020. 45 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1537309

ABSTRACT

Objetivo: Avaliar o efeito do tempo de exposição e do tipo de compósito na produção de artefato radiográfico na interface dente/material restaurador. Materiais e Métodos: Em 20 incisivos bovinos hígidos foram feitos preparos cavitários e restaurações classe II utilizando resinas compostas Filtek Bulk Fill One (gruo 1) e a Filtek Z350 (grupo 2). Em seguida, os dentes foram expostos para obtenção das radiografias digitais, variando o tempo de exposição em 0,07, 0,10, 0,14, 0,20 e 0,25s. As imagens foram avaliadas para investigação da presença de artefato através da análise do número de pixels modificado (QPXD) e do valor médio de cinza nas restaurações de classe II (MGVR), utilizando o software Image J (Instituto Nacional de Saúde, Bethesda, MD, EUA). Resultados: Observou-se a presença de artefato em toda amostra avaliada, independente de tipo de material restaurador e tempo de exposição empregado. Não se observou diferença estatisticamente significante na QPXD e nos MGVR entre as resinas utilizadas (ANOVA 2 fatores, p p>0,05). A análise do MGVR indicou que não houve diferenças estatisticamente significativas entre as resinas nem entre os tempos de exposição (p>0,05). Observou-se uma correlação entre a QPXD e o MGVR (r=0,29) para a resina Filtek Bulk Fill One. Conclusão: Foi identificado a presença de pixels alterados sobre a dentina na região da interface dente-restauração em todos os corpos de prova. A variação do tempo de exposição como também o tipo do compósito restaurador não influenciou no aumento ou diminuição do QPXD e nem tão pouco no MGVR. Contudo houve correlação entre o QPXD e o MGVR para a resina Filtek Bulk Fill One. Pesquisas adicionais são necessárias para determinar se o QPXD representa um artefato verdadeiro ou desajuste do material restaurador ou deficiência na aplicação sistema adesivo (AU).


Objective: To evaluate the effect of the exposure time and the type of composite in the production of radiographic artifact at the tooth / restorative interface. Materials and Methods: In 20 healthy bovine incisors, cavity preparations and class II restorations were made using composite resins Filtek Bulk Fill One (group 1) and Filtek Z350 (group 2). Then, the teeth were exposed to obtain digital radiographs, varying the exposure time by 0.07, 0.10, 0.14, 0.20 and 0.25s. The images were evaluated for investigation of the presence of artifact through the analysis of the modified number of pixels (QPXD) and the average gray value in class II (MGVR) restorations, using the Image J software (National Health Institute). Results: The presence of artifact was observed in all evaluated samples, regardless of the type of restorative material and the exposure time employed. There was no statistically significant difference in QPXD and MGVR between the resins used (ANOVA 2 factors, p p> 0.05). The MGVR analysis indicated that there were no statistically significant differences between resins or between exposure times (p> 0.05). There was a correlation between QPXD and MGVR (r = 0.29) for Filtek Bulk Fill One resin. Conclusion: The presence of altered pixels on dentin in the region of the tooth-restoration interface was identified in all specimens. The variation in the exposure time as well as the type of the restorative composite did not influence the increase or decrease of QPXD and neither in MGVR. However, there was a correlation between QPXD and MGVR for Filtek Bulk Fill One resin. Further research is needed to determine whether QPXD represents a true artifact or misfit of the restorative material or deficiency in the adhesive system application (AU).


Subject(s)
Animals , Cattle , Artifacts , Composite Resins/chemistry , Radiography, Dental, Digital/instrumentation , Incisor , In Vitro Techniques/methods , Analysis of Variance
5.
Dent. press endod ; 9(3): 20-28, Sept-Dec.2019.
Article in English | LILACS | ID: biblio-1343623

ABSTRACT

As conquistas incorporadas à Endodontia em decorrência das novas tecnologias de informação permitiram avanços que impactaram no êxito clínico e no prognóstico. Essas novas aquisições influenciaram o mundo contemporâneo, que presencia uma profunda mudança proporcionada pela velocidade e qualidade das informações, economia de investimento e tempo, assim beneficiando a área da saúde. Uma revolução do pensamento e modo de viver contemporâneo que se experimenta nos dias atuais é a biotecnologia. O impacto da tomografia computadorizada de feixe cônico na Endodontia foi capaz de superar várias limitações das radiografias periapicais, como a eliminação das sobreposições, a extraordinária possibilidade de navegação pela imagem, a qualidade das imagens em alta resolução e contraste, entre outras. Esse estudo objetiva apresentar algumas características de um novo software de tomografia computadorizada de feixe cônico chamado de e-Vol DX, capaz de impactar nas tomadas de decisões clínicas em Endodontia. O software de TCFC e-Vol DX se constitui em um recurso imprescindível na obtenção de imagens de alta qualidade. Vários filtros, com diferentes propriedades, foram desenvolvidos e incorporados, como o filtro BAR, que permite a redução de artefatos de contraste do branco, entre outros. Essa ferramenta é efetiva em tomadas de decisões clínicas para a execução do protocolo terapêutico de casos endodônticos complexos.


The achievements incorporated into endodontics, resulting from new information technologies allowed advances that impacted prognosis and clinical success. These new acquisitions have influenced the contemporary world, that is witnessing a profound change brought about by the speed and quality of information, investment savings and time, thus benefiting the health areas. A revolution in contemporary thinking and living that is being experienced today is biotechnology. The impact of cone beam computed tomography on endodontics was able to overcome several limitations of periapical radiography, such as the removal of overlaps, the extraordinary possibility of image navigation, the quality of high resolution and contrast images, among others. This study aims to present some characteristics of a new cone beam computed tomography software named e-Vol DX which may impact the clinical decision-making in endodontics. The e-Vol DX CBCT software is an indispensable resource for high quality images. Various filters with different properties have been developed and incorporated, such as the Blooming Artifact Reduction (BAR) filter that allows the reduction of white contrast artifacts, among others. This tool is effective in clinical decision-making for the implementation of the therapeutic protocol of complex endodontic cases.


Subject(s)
Software , Artifacts , Endodontics , Information Technology , Cone-Beam Computed Tomography , Diagnosis , Investments
6.
Pesqui. vet. bras ; 38(11): 2099-2108, Nov. 2018. ilus
Article in English | LILACS, VETINDEX | ID: biblio-976408

ABSTRACT

This study stems from the findings during the gross and histopathological exam of 3,338 cattle brains as part of the bovine spongiform encephalopathy (BSE) active surveillance program of the Brazilian Ministry of Agriculture, Livestock, and Supply from 2001 to 2005. The work was carried out in the Veterinary Pathology Laboratory of the Federal University of Santa Maria which at the time (2001-2007) was the national reference laboratory for the diagnosis of BSE and other transmissible spongiform encephalopathies. Both gross and histopathological aspects are described. Several gross aspects were annotated: anatomic normal structures not commonly recognized (non-lesions), lesions of no clinical significance, postmortem changes and artifacts; all these can amount to important pitfalls that distract the pathologist during the routine gross examination of the central nervous system (CNS). Accordingly, equivalent pitfalls were described in the histological examination. Non-lesions observed were the pineal body, embryo remnants such as the external germinal layer of the cerebellum, subependymal plates, and clusters of neuroblasts in the basal ganglia; or circumventricular structures such as area postrema, subcomisural organ, and melanosis in the leptomeninges and vessel walls. Lesions with little or no clinical importance included age-related changes as lipofuscin, hemosiderin, mineralization and hyalinization of vessel walls within the brain and meninges. Corpora amylacea and corpora arenacea were detected respectively in astrocyte processes and the pineal body. Cytoplasmic neuronal vacuolization was observed in the red nucleus and habenular nucleus. Sarcocystis sp. without a correspondent inflammatory reaction was rarely observed. Included within findings with no clinical manifestation were axonal spheroids and perivascular mononuclear cuffings. Changes in the CNS due to killing, sampling and fixation methods can obscure or distract from the more critical lesions. The ones related to the process of killing included hemorrhages caused in cattle destroyed by a captive bolt. Artifacts related to sampling and handling of CNS tissue consisted of inclusion of bone sand in the neural tissue from sawing the calvarium; dark neurons produced by excessive handling of the brain, and micro-organisms that contaminated the tissues during sampling or histological processing. Postmortem autolytic or putrefactive changes observed included vacuolar changes in the myelin sheath, clear halos surrounding neurons and oligodendrocytes, clusters of putrefaction bacilli within vessels or dispersed throughout the brain tissue associated or not to clear halos. One interesting, and somewhat frequent, postmortem autolytic change found in the bovine brain was the partial dissolution of the granule cell layer (GCL) of the cerebellum, also referred to as conglutination of the GCL or as the French denomination "état glace". Due to the shortage of comprehensive publications in the subject, this review is intended to address the main pitfalls that can be observed in the brain of cattle hoping to help other pathologists avoiding misinterpret them.(AU)


Os resultados deste estudo foram obtidos pelo exame macroscópico e histopatológico de 3.338 cérebros de bovinos examinados durante o programa de vigilância ativa da encefalopatia espongiforme bovina (BSE) do Ministério da Agricultura, Pecuária e Abastecimento (MAPA), de 2001 a 2005. O trabalho foi realizado no Laboratório de Patologia Veterinária (LPV) da Universidade Federal de Santa Maria (UFSM) que, de 2001 a 2007, foi o laboratório nacional de referência para o diagnóstico da BSE e de outras encefalopatias espongiformes transmissíveis. Macroscopicamente, foram descritas estruturas anatômicas normais (não-lesões), mas que são, com frequência, interpretadas como lesões; lesões sem significado clínico; alterações pós-mortais e artefatos. Esses achados podem confundir e desviar a atenção do patologista durante o exame de rotina do sistema nervoso central (SNC). Da mesma forma, estruturas equivalentes foram descritas no exame histológico. As não-lesões observadas foram corpo pineal, remanescentes embrionários, como a camada germinativa externa do cerebelo, placas subependimárias e aglomerados de neuroblastos nos gânglios da base; ou estruturas circunventriculares, como área de postrema, órgão subcomissural e melanose em leptomeninges e paredes dos vasos. Lesões com pouca ou nenhuma importância relacionadas ao envelhecimento incluíram lipofuscina, hemossiderina, mineralização, hialinização das paredes dos vasos do encéfalo e das meninges. Corpora amylacea foram detectados em processos astrocíticos e corpora arenacea, no corpo pineal. Adicionalmente, foi observada vacuolização no citoplasma de neurônios do núcleo vermelho e do núcleo habenular. Sarcocystis sp. sem reação inflamatória correspondente foi raramente observado. Incluídos nos achados sem manifestação clínica estavam esferóides axonais e manguitos mononucleares perivasculares. Alterações no SNC causadas pelo método de abate, amostragem e fixação podem simular ou obscurecer lesões mais importantes. Aquelas relacionadas ao método de abate incluíram hemorragias causadas em bovinos dessensibilizados pelo dardo cativo ou por punção por faca da medula na articulação atlanto-occipital. Artefatos relacionados à amostragem e manuseio de tecido do SNC consistiram na inclusão de pó de osso no tecido neural em consequência do uso de serra para abrir a caixa craniana; neurônios escuros produzidos pelo manuseio excessivo do cérebro e micro-organismos que contaminaram os tecidos durante a amostragem ou processamento histológico. Alterações autolíticas pós-mortais ou de putrefação incluíram vacuolizações na bainha de mielina, halos claros em torno dos neurônios e oligodendrócitos, aglomerados de bacilos de putrefação dentro dos vasos ou dispersos em todo o tecido cerebral, relacionados ou não a halos claros. Uma alteração autolítica pós-mortal intrigante e relativamente frequente encontrada foi a dissolução parcial da camada de células granulares (CCG) do cerebelo, também referida como conglutinação da CCG ou "état glacé". Devido à escassez de publicações abrangentes neste assunto, esta revisão pretende abordar as principais ciladas que possam aparecer no cérebro de bovinos, na esperança de ajudar outros patologistas a evitar interpretá-las erroneamente.(AU)


Subject(s)
Animals , Cattle , Brain/anatomy & histology , Cattle/anatomy & histology , Cattle Diseases/physiopathology , Encephalopathy, Bovine Spongiform/physiopathology , Autopsy/veterinary
7.
Arq. bras. oftalmol ; 80(4): 257-259, July-Aug. 2017. graf
Article in English | LILACS | ID: biblio-888133

ABSTRACT

ABSTRACT This case report describes a 19-year-old Caucasian man presented with decreased visual acuity in the right eye for 3 months. Dilated funds exam revealed optic disk pit associated with serous macular detachment. Optical coherence tomography identified communication between the optic disk pit and the macular serous detachment, and optical coherence tomography angiography displayed a subfoveal area suggestive of subfoveal choroidal neovascularization. However, there was no evidence of leakage in the fluorescein angiogram and no evidence of choroidal neovascularization in optical coherence tomography in the area corresponding to the suspicious subfoveal choroidal neovascularization. The patient underwent 23-gauge pars plana vitrectomy in the right eye. Six weeks after surgery, multimodal imaging was repeated and there was near-complete resorption of the subretinal fluid. Optical coherence tomography angiography signal superimposed on optical coherence tomography B-scan also demonstrated normal choriocapillaris signal throughout the macula. In conclusion, optical coherence tomography angiography may produce artifacts in optic disk pit maculopathy that simulate choroidal neovascularization.


RESUMO O presente estudo relatou o caso de um homem caucasiano de 19 anos com diminuição da acuidade visual no olho direito há 3 meses. Na fundoscopia havia um pit de papila associado ao descolamento seroso macular. A tomografia de coerência óptica identificou uma comunicação entre o pit e o descolamento seroso e a angiografia por tomografia de coerência óptica demonstrou uma área subfoveal sugestiva de membrana neovascular sub-retiniana. No entanto, não houve evidência de vazamento na angiofluoresceínografia com contraste e nem de membrana neovascular sub-retiniana na tomografia de coerência óptica na área suspeita. O paciente foi submetido a vitrectomia pars plana 23-gauge no olho direito. Seis semanas após a cirurgia, os exames foram repetidos e houve reabsorção quase completa do líquido sub-retiniano. O sinal da angiografia por tomografia de coerência óptica sobreposto à tomografia de coerência óptica B-scan era normal na região da mácula. Em conclusão, a angiografia por tomografia de coerência óptica pode produzir artefatos em maculopatia secundária a pit de papila que simulam uma membrana neovascular sub-retiniana.


Subject(s)
Humans , Male , Young Adult , Optic Disk/diagnostic imaging , Fluorescein Angiography/methods , Artifacts , Choroidal Neovascularization/diagnostic imaging , Tomography, Optical Coherence/methods , Retinal Detachment/diagnostic imaging , Visual Acuity
8.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 27(3): 220-228, set.-dez. 2015.
Article in Portuguese | LILACS, BBO | ID: lil-786421

ABSTRACT

A imagem é uma importante ferramenta de diagnóstico para a avaliação do paciente odontológico. E desde o advento da tomografia computadorizada por Ambrose1 em 1973, o diagnóstico e o planejamento dos tratamentos ganharam um grande aliado. As tomografias computadorizadas são técnicas imaginológicas onde se obtêm imagens em diversos planos com uma fidelidade das mensurações muito próximas à realidade. Entretanto, o diagnóstico pode ser dificultado pela presença de artefatos. Nesta revisão de literatura, o enfoque será aos artefatos metálicos. A imagem produzida pelos artefatos frequentemente interferem na visualização de estruturas anatômicas, podendo confundir o diagnóstico. O objetivo do presente artigo é explicar brevemente a tomografia computadorizada cone beam, a formação de imagem nesse tipo de tomografia e o que são e como são gerados os artefatos metálicos, esclarecendo aspectos ligados a sua formação, características que proporcionam às imagens e ideias de solução desse problema que constantemente prejudicam o diagnóstico por imagem nessa modalidade de exame. Pode-se concluir que a diminuição do aparecimento de artefatos pode ser devido à calibração adequada do aparelho, orientação ao paciente sobre o procedimento a ser realizado, além da atenuação com equipamentos e softwares que utilizam campo de visão e tamanho de voxel pequenos. E os profissionais que trabalham com tomografia computadorizada devem estar preparados para identicá-los, solicitando outros exames complementares para realizar diagnóstico diferencial, caso seja necessário


This is an important diagnostic tool for Evaluating the dental patient. Since the advent of computed tomography (CT) by Ambrose1 in 1973, the diagnosis and planning of treatment have gained a great ally. CT scans are imaginological techniques where you get images in different planes with a fidelity of measurements very close to reality. However, diagnosis can be hindered by the presence of artifacts. The main focus of this review was the metallic artifacts and subjects related to them. The image produced by metallic artifacts often interferes with visualization of anatomical structures and may lead to misdiagnosis. The purpose of this article is to briefly explain the computerized cone beam tomography, the imaging in this type of tomography and what they are and how the metal artifacts are generated, clarifying aspects related to their formation, characteristics that give images, solution and ideas to this problem that constantly damage the imaging examination in this mode. It can be concluded that the decrease in the appearance of artifacts may be due to proper calibration of the device, the patient guidance on the procedure to be performed, as well as mitigation with equipment and software using of view and small voxel size. We can conclude that the professionals who work with computed tomography should be prepared to identify them and ask for other exams to perform differential diagnosis, if necessary


Subject(s)
Artifacts , Cone-Beam Computed Tomography
9.
Radiol. bras ; 48(4): 242-248, July-Aug. 2015. ilus
Article in English | LILACS | ID: lil-759414

ABSTRACT

AbstractMagnetic resonance imaging has revolutionized the diagnosis of shoulder lesions, in many cases becoming the method of choice. However, anatomical variations, artifacts and the particularity of the method may be a source of pitfalls, especially for less experienced radiologists. In order to avoid false-positive and false-negative results, the authors carried out a compilation of imaging findings that may simulate injury. It is the authors’ intention to provide a useful, consistent and comprehensive reference for both beginner residents and skilled radiologists who work with musculoskeletal magnetic resonance imaging, allowing for them to develop more precise reports and helping them to avoid making mistakes.


ResumoA ressonância magnética revolucionou o diagnóstico de lesões do ombro, tornando-se, em muitos casos, o método de escolha. No entanto, as variações anatômicas, artefatos e particularidade do método podem ser fonte de armadilhas, especialmente para radiologistas menos experientes. Para evitar resultados falso-positivos e falso-negativos, foi realizada uma compilação de achados de imagem que podem simular lesões. Pretendemos ser uma referência útil, consistente e abrangente para os residentes iniciantes e radiologistas qualificados que trabalham com ressonância magnética musculoesquelética, a fim de desenvolver relatórios mais precisos e ajudá-los a evitar erros.

10.
Rev. Assoc. Med. Bras. (1992) ; 60(4): 311-317, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-720985

ABSTRACT

Objective: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U). The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D). Methods and Results: we performed U acquisition and in sequence D acquisition in 120 patients (pts) using a one-day MPI (rest-gated/stress), with 99mTc-sestamibi (370 MBq and 1110 MBq). Images were processed by the iterative reconstruction method (OSEM). Rest (R) and stress (S) studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes) were automatically obtained by the quantitative gated SPECT (QGS) program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or < 5%) and abnormal (SSS>3 or ≥ 5%). Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82) and SRS (p = 0.74) in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001) and SRS (Rho = 0.96 p = 0.0001), but the mean SSS (12.53 ± 7.54) and SRS (10.60 ± 7.08) values of D were significantly lower (p < 0.05) than SSS (13.43 ± 6.81) and SRS (11.33 ± 6.97) of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001). Conclusion: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the ...


Objetivo: no estudo de perfusão miocárdica, apesar dos avanços tecnológicos, continuamos utilizando o desconfortável e às vezes impraticável posicionamento em decúbito dorsal com braços acima da cabeça (U). O objetivo do estudo foi investigar se os resultados da perfusão e da função cardíacas obtidos com a aquisição U são equivalentes ao de outra modalidade de posição: com braços para baixo nas laterais do tronco (D). Métodos e resultados: adquirida a aquisição U, na sequência foi realizada a aquisição D em 120 pacientes (pts) em um único dia (repouso e estresse sincronizado ao ECG), com 99mTc-sestamibi (370 MBq e 1110 MBq). As imagens foram processadas usando reconstrução iterativa (OSEM). Cada estudo foi quantificado usando o modelo de 17-segmentos ao repouso (R) e ao estresse (S). Os parâmetros funcionais (fração de ejeção do ventrículo esquerdo e volumes) foram obtidas automaticamente pelo programa gated SPECT quantitativa (QGS). De acordo com a dimensão da alteração perfusional no estresse na aquisição U, os pacientes foram classificados em dois subgrupos: 80 pts normais (SSS ≤ 3 ou < 5%) e 40 pts anormais (SSS > 3 ou ≥ 5%). Dor no ombro e/ou nas costas ocorreu em 23,3% dos pacientes de U e em 5% de D. Não houve diferenças significativas entre U e D quanto ao SSS (p = 0,82) e SRS (p = 0,74) no grupo normal. No grupo anormal, boa correlação foi encontrada entre U e D para SSS (Rho = 0,95, p = 0,0001) e SRS (Rho = 0,96 p = 0,0001), entretanto a média dos valores de SSS (12,53 ± 7,54) e SRS (10,60 ± 7,08 ) de D foram significativamente menores (p < 0,05) que o SSS (13,43 ± 6,81) e SRS (11,33 ± 6,97) de U. As medidas de função apresentaram boas correlações, ...


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arm , Myocardial Perfusion Imaging/methods , Patient Positioning/methods , Supine Position , Tomography, Emission-Computed, Single-Photon/methods , Rest , Stroke Volume
11.
Arq. bras. cardiol ; 102(1): 86-92, 1/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-704041

ABSTRACT

Fundamento: Há poucos dados sobre a definição de parâmetros simples e robustos para predizer artefato de imagem em tomografia computadorizada (TC) cardíaca. Objetivos: Avaliar o valor da simples medida da espessura do tecido subcutâneo (espessura pele-esterno) como preditor de artefato de imagem em TC cardíaca. Métodos: O estudo avaliou 86 pacientes submetidos a angiotomografia computadorizada cardíaca (ATCC) com sincronização prospectiva com ECG e avaliação de escore de cálcio coronário com 120 kV e 150 mA. A qualidade da imagem foi medida objetivamente pelo artefato de imagem na aorta em ATCC, sendo 'artefato baixo' definido como aquele < 30 UH. Os diâmetros torácicos anteroposterior e laterolateral, o artefato de imagem na aorta e a espessura pele-esterno foram medidos como preditores de artefato em ATCC. A associação de preditores e artefato de imagem foi avaliada usando-se correlação de Pearson. Resultados: A dose média de radiação foi 3,5 ± 1,5 mSv. O artefato de imagem médio na ATCC foi de 36,3 ± 8,5 UH, sendo o artefato de imagem médiona fase sem contraste do exame de 17,7 ± 4,4 UH. Todos os preditores foram independentemente associados com artefato em ATCC. Os melhores preditores foram espessura pele-esterno, com correlação de 0,70 (p < 0,001), e artefato de imagem na fases em contraste,com correlação de 0,73 (p < 0,001). Ao avaliar a habilidade de predizer artefato de imagem baixo, as áreas sob a curva ROC para o artefato de imagem na fases em contraste e para a espessura pele-esterno foram 0,837e 0,864, respectivamente. Conclusão: Tanto espessura pele-esterno quanto artefato de escore de cálcio são preditores simples e precisos de artefato de imagem em ATCC. Tais parâmetros podem ser incorporados aos protocolos ...


Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure. .


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Artifacts , Aortography/methods , Coronary Angiography/methods , Subcutaneous Tissue , Tomography, X-Ray Computed/methods , Body Mass Index , Linear Models , Predictive Value of Tests , Radiation Dosage , Reference Values , Sensitivity and Specificity
12.
Arq. bras. oftalmol ; 76(1): 13-17, jan.-fev. 2013. ilus, graf, tab
Article in English | LILACS | ID: lil-678154

ABSTRACT

PURPOSE: To investigate the reliability of ultrasound in determining the size and identify the sonographic features and artifacts generated by intraocular foreign bodies of different materials. METHODS: Experimental study using 36 enucleated porcine eyes. Fragments of nine different compositions (wood, glass, plastic, cardboard, iron, aluminum, lead, powder and concrete) and similar dimensions (4 mm) were implanted via scleral incision into the vitreous cavity of 36 porcine eyes, four eyes were used for each material. Ultrasound examination was performed in all eyes using the contact technique, conductive gel and 10-MHz transducer (EZScan, Sonomed). RESULTS: Considering the material fragments of gunpowder, lead, concrete, aluminum, wood and glass, the size determined by ultrasound was considered statistically similar to the actual size. The material iron presented ultrasound-determined dimension statistically smaller than its actual size. Cardboard and plastic materials showed ultrasound-determined measurements far greater than the actual. All fragments of intraocular foreign bodies demonstrated hyper-reflective interfaces, irrespective of their composition. Whereas the artifacts generated by different materials, it was found that the materials iron, aluminum and lead showed reverberation of great extent. The material wood showed no reverberation. The length of the reverberation artifact for the materials iron, glass, aluminum and cardboard was lower when compared to other materials. All materials presented posterior shadowing artifact, with the exception of aluminum. CONCLUSION: Ultrasonography was considered a reliable technique to determine the size of intraocular foreign bodies in pigs, with little influence caused by its composition. Ultrasound artifacts generated were considered material-dependent and can assist the examiner to identify the nature of a foreign body of unknown etiology. Ultrasonography aided the surgeon to identify, locate and measure the intraocular foreign body, directing appropriate surgical planning.


OBJETIVO: Investigar a confiabilidade da ultrassonografia em determinar a dimensão e identificar as características ultrassonográficas e os artefatos gerados por corpos estranhos intraoculares de materiais diferentes. MÉTODOS: Estudo experimental, utilizando 36 olhos enucleados de origem suína. Fragmentos de nove diferentes composições (madeira, vidro, plástico, papelão, ferro, alumínio, chumbo, pólvora e concreto) e de dimensões similares (4 mm) foram implantados cirurgicamente via incisão escleral na cavidade vítrea de 36 olhos porcinos, 4 olhos para cada tipo de material. O exame ultrassonográfico foi realizado em todos os olhos utilizando-se a técnica de contato, gel condutor e transdutor de 10 MHz (EZScan, Sonomed). RESULTADOS: Considerando os fragmentos dos materiais pólvora, chumbo, concreto, alumínio, madeira e vidro, a dimensão determinada pela ultrassonografia foi considerada estatisticamente similar à dimensão real. O material ferro apresentou dimensão ultrassonográfica estatisticamente menor que sua dimensão real. Papelão e plástico demonstraram medida maior que o real. Todos fragmentos de corpos estranhos intraoculares demonstraram interfaces hiper-refletivas, independentemente da sua composição. Considerando os artefatos gerados pelos diferentes materiais, verificou-se que os materiais ferro, alumínio e chumbo apresentaram reverberação de grande extensão. O material madeira não apresentou reverberação. O comprimento do artefato de reverberação dos materiais ferro, vidro, alumínio e papelão foi menor quando comparado aos outros materiais. Todos materiais apresentaram artefato de sombreamento posterior, com exceção do alumínio. CONCLUSÃO: A ultrassonografia foi considerada uma técnica confiável para determinar a dimensão de corpos estranhos intraoculares em porcinos, com pouca influência causada pela sua composição. Artefatos gerados à ultrassonografia foram considerados material-dependentes e podem auxiliar o examinador a identificar a natureza de um corpo estranho de etiologia desconhecida. O auxílio diagnóstico nestes casos permite ao cirurgião identificar, localizar e dimensionar o corpo estranho intraocular, orientando um planejamento cirúrgico adequado.


Subject(s)
Animals , Eye Foreign Bodies , Artifacts , Eye Foreign Bodies/classification , Reproducibility of Results , Swine
13.
Acta bioeth ; 9(1): 9-19, 2003.
Article in Spanish | LILACS | ID: lil-626709

ABSTRACT

Por su propia naturaleza, los sistemas biotecnológicos generan tanto beneficios como riesgos y situaciones de incertidumbre y de ignorancia. Las evaluaciones de los sistemas biotecnológicos, de los artefactos que producen y de sus consecuencias en las sociedades y en la naturaleza, dependen tanto de valores constitutivos de esos sistemas biotecnológicos, como de diferentes valores externos a ellos, que varían de un grupo social a otro y que muy difícilmente llegan a coincidir completamente. Tal diversidad valorativa debe ser reconocida en los procesos de evaluación de la biotecnología, por ejemplo sobre cuestiones de bioseguridad, por parte de expertos y de diversos sectores sociales (agentes estatales, empresarios, organizaciones no gubernamentales, grupos ciudadanos). En consecuencia, deben establecerse instancias de participación de expertos de diferentes disciplinas naturales, sociales y humanísticas, así como de no expertos, representantes de los sectores sociales con intereses en juego, que vigilen el impacto de los sistemas biotecnológicos y de sus artefactos y que tengan capacidad de tomar decisiones y de realizar acciones para prevenir, paliar o contrarrestar efectos negativos de los sistemas biotecnológicos.


Due to their intrinsic nature, biotechnological systems produce both benefits as well as risks and situations of uncertainty and ignorance. The evaluations of biotechnological systems, of the artifacts produced by them and of their consequences for society and the environment, depend both on intrinsic values of those systems as well as on values extrinsic to them, which in turn vary from one social group to another and which can hardly coincide completely. Such axiological plurality must be taken into account in reviewing biotechnology, for example about biosafety issues by experts from different social sectors (state agents, managers, non governmental organizations, advocacy groups) Therefore, mechanisms of participation of experts from different natural, social and humanistic disciplines must be established, along with non experts representing the social sectors with interests. These will watch over the impact of biotechnological systems and their artifacts, they will be able to take decisions and carry out actions to prevent, mitigate or counteract the negative consequences of biotechnology.


Por sua própria natureza, os sistemas biotecnológicos geram tanto benefícios como riscos e situações de dúvidas e de ignorância. As avaliações dos sistemas biotecnológicos, dos artefatos que produzem e de suas conseqüências nas sociedades e na natureza, dependem tanto de valores constitutivos destes sistemas biotecnológicos, como de diferentes valores externos a eles, que variam de um grupo social a outro, e que muito dificilmente chegam a coincidir completamente. Tal diversidade valorativo deve ser reconhecida nos processos de avaliação biotecnológica, por exemplo sobre questões de biossegurança, por parte de experts e de diversos setores sociais (agentes estatais, empresários, organizações não governamentais, grupos de cidadãos). Consequentemente, devem estabelecerse instâncias de participação de experts de diferentes, disciplinas naturais, sociais e humanisticas, bem como de não peritos, representantes de setores sociais com interesses em jogo, que vigiem o impacto dos sistemas biotecnológicos e de seus artefatos, e que tenham capacidade de decidir e de realizar ações para prevenir, ou enfrentar os efeitos negativos dos sistemas biotecnológicos.


Subject(s)
Humans , Philosophy , Societies , Biotechnology , Artifacts , Nature , Decision Making
14.
Rev. bras. farmacogn ; 12(1): 21-26, 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-526492

ABSTRACT

A partir do fracionamento em coluna de gel de sílica do extrato clorofórmico de Polygala paniculata (Polygalaceae), foram isolados 7-metóxi-8-(1',2'-epóxi-3'-metil-3'-butenil)-cumarina (1) e dois artefatos cumarínicos (2a-2b), formados a partir da abertura do anel epóxido de 1 durante o processo de isolamento. O tratamento de 1 com EtOH/SiO2, sob agitação e à temperatura ambiente durante 24 horas, resultou na formação dos respectivos artefatos: 7-metóxi-8-(1'-hidróxi-2-etóxi-3'-metil-3'-butenil)-cumarina (2a) e 7-metóxi-8-(1'-etóxi-2-hidróxi-3'-metil-3'-butenil)-cumarina (2b). As estruturas químicas desses compostos foram determinadas através da análise de seus dados espectrais, incluindo RMN bidimensional.


Fractionation of a chloroform extract of Polygala paniculata (Polygalaceae) on silica gel column chromatography yielded 7-methoxy-8-(1',2'-epoxy-3'-methyl-3'-butenyl)-coumarin (1) and two coumarinic artifacts (2a-2b). The reaction of 1 with EtOH/SiO2 at room temperature for 24 hours yielded 7-methoxy-8-(1'-hydroxy-2'-ethoxy-3'-methyl-3'-butenyl)-coumarin (2a) and 7-methoxy-8-(1'-ethoxy-2'-hydroxy-3'-methyl-3'-butenyl)-coumarin (2b). The structures have been determined by spectral data, including 2D NMR experiments.

SELECTION OF CITATIONS
SEARCH DETAIL